Professional Electrical Construction and Maintenance Services from 22kV to 0.4kV at QuangAnhcons

Introduction to Electrical Construction and Maintenance Services from 22kV to 0.4kV at QuangAnhcons

QuangAnhcons is proud to offer comprehensive electrical construction and maintenance services for systems ranging from 22kV to 0.4kV, catering to new factory construction, ongoing operations, and factory relocations. With our team of experienced professionals, we ensure safety, efficiency, and timely completion of all projects.

For New Factory Construction

  1. Survey and Design:
    • Conduct field surveys and assess the factory’s electrical needs.
    • Design electrical systems from 22kV to 0.4kV, including network diagrams, electrical panels, and control systems.
  2. Supply and Installation of Equipment:
    • Supply and install transformers, distribution panels, medium voltage cabinets, and low voltage cabinets.
    • Install power and control cables, cable trays, and conduit systems.
  3. Construction of Lighting and Power Systems:
    • Install indoor and outdoor lighting systems.
    • Install power systems for machinery and production equipment.
  4. Protection and Safety Systems:
    • Install lightning protection and grounding systems.
    • Install overload and short circuit protection systems.
  5. Inspection and Testing:
    • Inspect the entire system before operation.
    • Test and calibrate equipment to ensure stable and safe operation.

For Ongoing Factory Operations

electrical system contractor

  1. Periodic Electrical System Maintenance:
    • Regularly inspect and maintain electrical equipment such as transformers, electrical panels, and cable systems.
    • Inspect and maintain lighting systems and cable trays.
  2. Electrical System Repair and Upgrades:
    • Repair electrical faults and replace damaged equipment.
    • Upgrade electrical systems to meet expanded production needs or improve operational efficiency.
  3. Energy Monitoring and Management:
    • Monitor power consumption and manage energy to optimize operating costs.
    • Provide energy-saving solutions and improve electrical efficiency.

For Factory Relocation

electrical system contractor

  1. Planning and Surveying:
    • Develop a detailed plan for the relocation of the electrical system.
    • Survey the current state and create a relocation plan for the electrical system from the old location to the new one.
  2. Dismantling and Packaging Equipment:
    • Dismantle transformers, electrical panels, cable systems, and related equipment.
    • Package and transport equipment to the new location.
  3. Reinstallation and Connection of Electrical Systems:
    • Reinstall transformers, electrical panels, and cable systems at the new location.
    • Connect the electrical system to the new site’s power grid.
  4. Inspection and Testing:
    • Inspect the entire system after reinstallation to ensure safety and stable operation.
    • Test and calibrate the system to ensure optimal performance.
  5. Technical Support and Supervision:
    • Provide technical support during the relocation and reinstallation process.
    • Supervise the relocation to ensure project quality and adherence to schedules.

QuangAnhcons accompanies you in every phase of your project, from design and construction to maintenance and relocation of electrical systems. Contact us for dedicated and professional support.

electrical system contractor

Quang Anh CE Co., LTD

Office: Unit 02, 08th floor, Pearl Plaza Building, 561A Dien Bien Phu Street, Ward 25, Binh Thanh District, Ho Chi Minh City, Vietnam
Hotline: 0919758191
Website: https://quanganhcons.com/

QUANGANHCONS

Substation budget estimate

Select the capacity, route lengths and package to view your indicative budget and electrical parameters.

01   Quick estimate

Cable and power-factor correction conditions
Request a project quotation

Send your project details, BOQ or drawings to request a formal quotation. Fields marked * are required.

Reference quick estimate
No quick estimate yet. You can still submit a project quotation request.

Quotation scope

Applies to one EVN-supplied substation with oil-immersed transformers at 22/0.4 kV (single-phase: 12.7/0.23 kV), with MV metering VTs/CTs supplied by EVN. The estimate includes the selected equipment, installation, earthing, transformer-to-main-breaker connections, design and connection documentation, and coordination of testing and utility acceptance.

Kiosk, integrated steel-pole and indoor substations include MV switchgear and the entered underground cable route. Other outdoor arrangements use the relevant protection configuration. The final diagram must meet the project connection requirements.

Excludes VAT, cables from the substation switchboard to the MSB/loads, live-line work, harmonic reactors, weak-ground treatment or special piling, land and special fire-protection provisions. Underground routes assume normal construction conditions and exclude road drilling and special reinstatement.

Prices are indicative investment budgets. A formal quotation follows site assessment and agreement on the configuration. Electrical selections are preliminary and require design verification before installation.

Capacity range and application conditions

The catalogue defines the enquiry range of this tool, not universal TCVN capacity limits. Single pole-mounted transformers: 15–100 kVA; three-unit banks: 3×15–3×100 kVA. Platform substations: 100–630 kVA. Steel-pole substations: 100–630 kVA; 750/800 kVA require design verification and local approval. Ground-mounted, kiosk and indoor configurations: 50–10,000 kVA. Not every configuration has a package price or the same structural design.

Reference: EVN Decision 1299/QD-EVN dated 3 November 2017, Volume 1, sections 3.3–3.4. Check the current requirements of the responsible utility before implementation. Kiosks must meet manufacturer ratings and testing requirements (IEC 62271-202); indoor and ground-mounted arrangements must meet project layout, ventilation, structural and fire-protection requirements. For multiple transformers, specify the quantity and capacity of each unit.

Developed by QuangAnhcons · © 2026 QuangAnhcons. Code licensed under GPL-2.0-or-later. Standards and manufacturer data belong to their respective owners.