Substation Transformers
Quang Anh CGTE is the largest independent provider of substation transformers VietNam. Our liquid-filled, substation transformers are the ideal choice for commercial, industrial, and utility applications.
Quang Anh CGTE offers customized solutions. We are able to provide customized solutions for each unique challenge. Our team is flexible and knowledgeable and can provide customized design, guidance, and support while reacting rapidly to requests. And our extensive inventory of rebuilt substation transformers makes quick delivery possible.
An environmentally responsible solution. Rebuilt substation transformers are eco-friendly. Here at Quang Anh CGTE , we buy and rebuild surplus substation transformers and put them to work for utility companies large and small. From an environmental standpoint, purchasing a rebuilt substation is highly efficient.
We buy and sell! Quang Anh CGTE specializes in sales and service of substation transformers, as well as distribution transformers, reclosers, and voltage regulators. So, if you’re buying or selling a substation transformer, contact Quang Anh CGTE No.17 1st, Phuoc Long B ward, 09 dist, Ho Chi Minh City, VietNam
Quang Anh CGTE specializes in sales and service of oil-filled transformers and distribution transformers. We also offer technical support to the electrical distribution industry, as well as repair, recycling, and disposal of transformers and regulators. For more information or to request a quote, please click here to contact our sales and procurement team.
Substation budget estimate
Select the capacity, route lengths and package to view your indicative budget and electrical parameters.
Request a project quotation
Send your project details, BOQ or drawings to request a formal quotation. Fields marked * are required.
Quotation scope
Applies to one EVN-supplied substation with oil-immersed transformers at 22/0.4 kV (single-phase: 12.7/0.23 kV), with MV metering VTs/CTs supplied by EVN. The estimate includes the selected equipment, installation, earthing, transformer-to-main-breaker connections, design and connection documentation, and coordination of testing and utility acceptance.
Kiosk, integrated steel-pole and indoor substations include MV switchgear and the entered underground cable route. Other outdoor arrangements use the relevant protection configuration. The final diagram must meet the project connection requirements.
Excludes VAT, cables from the substation switchboard to the MSB/loads, live-line work, harmonic reactors, weak-ground treatment or special piling, land and special fire-protection provisions. Underground routes assume normal construction conditions and exclude road drilling and special reinstatement.
Prices are indicative investment budgets. A formal quotation follows site assessment and agreement on the configuration. Electrical selections are preliminary and require design verification before installation.
Capacity range and application conditions
The catalogue defines the enquiry range of this tool, not universal TCVN capacity limits. Single pole-mounted transformers: 15–100 kVA; three-unit banks: 3×15–3×100 kVA. Platform substations: 100–630 kVA. Steel-pole substations: 100–630 kVA; 750/800 kVA require design verification and local approval. Ground-mounted, kiosk and indoor configurations: 50–10,000 kVA. Not every configuration has a package price or the same structural design.
Reference: EVN Decision 1299/QD-EVN dated 3 November 2017, Volume 1, sections 3.3–3.4. Check the current requirements of the responsible utility before implementation. Kiosks must meet manufacturer ratings and testing requirements (IEC 62271-202); indoor and ground-mounted arrangements must meet project layout, ventilation, structural and fire-protection requirements. For multiple transformers, specify the quantity and capacity of each unit.
Developed by QuangAnhcons · © 2026 QuangAnhcons. Code licensed under GPL-2.0-or-later. Standards and manufacturer data belong to their respective owners.