In these substations, the apparatus is installed within the substation building. Such substations are usually for a voltage up to 22 KV but can be erected for 35KV when the surrounding atmosphere is contaminated with impurities such as metal corroding gases and fumes, conductive dust etc. The switchgear on supply or primary side will consist of oil circuit breakers only.
The high voltage supply is given to the primary of the transformer through circuit breaker. From the bus-bar various feeders emerge out. The panel for each feeder consists of an isolator switch and circuit breaker. In addition to isolator and circuit breaker, the panel is provided with the measuring instruments. As regards protection of feeders usually reverse power relay is employed. For the protection of oil filled transformers with conservator tanks relay is most common.
Quang Anh CGTE build indoor substation or Substations which the apparatus is equipped inside the substation building to fit specific applications from 320KVA through 4000KVA, with primary voltage ratings up to 22kv. In addition, we have three-phase outdoor substations from 320KVA to 4000KVA.
Substation budget estimate
Select the capacity, route lengths and package to view your indicative budget and electrical parameters.
Request a project quotation
Send your project details, BOQ or drawings to request a formal quotation. Fields marked * are required.
Quotation scope
Applies to one EVN-supplied substation with oil-immersed transformers at 22/0.4 kV (single-phase: 12.7/0.23 kV), with MV metering VTs/CTs supplied by EVN. The estimate includes the selected equipment, installation, earthing, transformer-to-main-breaker connections, design and connection documentation, and coordination of testing and utility acceptance.
Kiosk, integrated steel-pole and indoor substations include MV switchgear and the entered underground cable route. Other outdoor arrangements use the relevant protection configuration. The final diagram must meet the project connection requirements.
Excludes VAT, cables from the substation switchboard to the MSB/loads, live-line work, harmonic reactors, weak-ground treatment or special piling, land and special fire-protection provisions. Underground routes assume normal construction conditions and exclude road drilling and special reinstatement.
Prices are indicative investment budgets. A formal quotation follows site assessment and agreement on the configuration. Electrical selections are preliminary and require design verification before installation.
Capacity range and application conditions
The catalogue defines the enquiry range of this tool, not universal TCVN capacity limits. Single pole-mounted transformers: 15–100 kVA; three-unit banks: 3×15–3×100 kVA. Platform substations: 100–630 kVA. Steel-pole substations: 100–630 kVA; 750/800 kVA require design verification and local approval. Ground-mounted, kiosk and indoor configurations: 50–10,000 kVA. Not every configuration has a package price or the same structural design.
Reference: EVN Decision 1299/QD-EVN dated 3 November 2017, Volume 1, sections 3.3–3.4. Check the current requirements of the responsible utility before implementation. Kiosks must meet manufacturer ratings and testing requirements (IEC 62271-202); indoor and ground-mounted arrangements must meet project layout, ventilation, structural and fire-protection requirements. For multiple transformers, specify the quantity and capacity of each unit.