我们的企业正在寻找会讲中文的电气工程师加入我们在越南的团队。在这个职位上,您将直接参与电力系统和变电站的建设项目。您的工作将包括提供技术解决方案、确定客户要求,并与承包商和合作伙伴合作,确保项目按照规定时间和质量完成。您将在一个多元文化的环境中工作,与来自中国的技术专家团队一起工作。
我们正在寻找拥有电气工程本科学位、在电力领域有工作经验并具备基本中文沟通能力的候选人。如果您符合以上要求并对这个领域感兴趣,我们希望能与您合作。
此职位的薪水为1000-1500美元,取决于候选人的经验和对企业项目的贡献能力。我们也提供优厚的福利,包括保险、奖金和表彰卓越工作的奖励。
如果您对这个职位感兴趣,请将您的求职信发送给我们,我们会尽快与您联系。我们希望能够欢迎您加入我们的团队,共同为企业的发展做出贡献。

Substation budget estimate
Select the capacity, route lengths and package to view your indicative budget and electrical parameters.
Request a project quotation
Send your project details, BOQ or drawings to request a formal quotation. Fields marked * are required.
Quotation scope
Applies to one EVN-supplied substation with oil-immersed transformers at 22/0.4 kV (single-phase: 12.7/0.23 kV), with MV metering VTs/CTs supplied by EVN. The estimate includes the selected equipment, installation, earthing, transformer-to-main-breaker connections, design and connection documentation, and coordination of testing and utility acceptance.
Kiosk, integrated steel-pole and indoor substations include MV switchgear and the entered underground cable route. Other outdoor arrangements use the relevant protection configuration. The final diagram must meet the project connection requirements.
Excludes VAT, cables from the substation switchboard to the MSB/loads, live-line work, harmonic reactors, weak-ground treatment or special piling, land and special fire-protection provisions. Underground routes assume normal construction conditions and exclude road drilling and special reinstatement.
Prices are indicative investment budgets. A formal quotation follows site assessment and agreement on the configuration. Electrical selections are preliminary and require design verification before installation.
Capacity range and application conditions
The catalogue defines the enquiry range of this tool, not universal TCVN capacity limits. Single pole-mounted transformers: 15–100 kVA; three-unit banks: 3×15–3×100 kVA. Platform substations: 100–630 kVA. Steel-pole substations: 100–630 kVA; 750/800 kVA require design verification and local approval. Ground-mounted, kiosk and indoor configurations: 50–10,000 kVA. Not every configuration has a package price or the same structural design.
Reference: EVN Decision 1299/QD-EVN dated 3 November 2017, Volume 1, sections 3.3–3.4. Check the current requirements of the responsible utility before implementation. Kiosks must meet manufacturer ratings and testing requirements (IEC 62271-202); indoor and ground-mounted arrangements must meet project layout, ventilation, structural and fire-protection requirements. For multiple transformers, specify the quantity and capacity of each unit.
Developed by QuangAnhcons · © 2026 QuangAnhcons. Code licensed under GPL-2.0-or-later. Standards and manufacturer data belong to their respective owners.
English
Tiếng Việt
Deutsch
日本語
한국어
ไทย
Русский
Français