QuangAnhcons | 100 kWp reference PV simulation | English edition 05 Nov 2026

Numeric CSV data are unchanged from the approved Vietnamese 100 kWp product.
DC 100.48 kWp / AC limit 90 kW. JRC PVGIS 5.3 ERA5 2023.
12 monthly rows, 8760 source hours, 24 mean local-hour slots.
Direct consumption was calculated per source hour before aggregation/averaging.
The representative-day curve is a 365-observation mean per local slot, not a sunny 15 March example.
Assumed zero export; surplus is curtailed. No battery dispatch or project-meter data.
The source, parameter and numerical limitations in energy-summary.json remain applicable.
Source PDF/XLSX amounts and Vietnamese originals are not changed by this package.